    摘要:

    【目的】为研究黏滞阻尼器对仿古建筑的力学性能的影响,通过设置仿古建筑梁-柱节点来开展试件的对比试验研究。【方法】设计制作了6个仿古建筑梁-柱节点,即3个双梁-柱节点及3个单梁-柱节点,并对其施加正弦波往复荷载以研究其一系列力学性能,主要包括荷载-转角滞回曲线、骨架曲线、承载能力、变形性能、耗能能力等。【结果】在整体上,黏滞阻尼器对双梁-柱节点力学性能的改善程度比对单梁-柱节点的更为显著,且改善程度随黏滞阻尼器型号不同而不同。在附设黏滞阻尼器后,梁-柱节点试件的滞回曲线更饱满,承载能力提升了16.4%~32.9%,位移延性系数增大了1.5%~12.6%,耗能能力提升了49.2%~112.3%。【结论】黏滞阻尼器可显著改善仿古建筑梁-柱节点的力学性能。

    Abstract:

    [Purposes] In order to study the influence of viscous dampers on the mechanical properties of pseudo-classic architecture, a comparative experiment for lintel-column joint specimens of pseudo-classic architecture was carried out. [Methods] Six lintel-column joints of pseudo-classic architecture were designed and produced, including three dual-lintel-column joints and three single-lintel-column joints, and their mechanical properties were studied by applying reciprocating sinusoidal wave loads, such as the load-angle hysteresis curve, skeleton curve, load carrying capacity, deformation capacity, and energy dissipation capacity. [Findings] Overall, the improvement degree of viscous dampers on the mechanical properties of dual-lintel-column joints is more significant than that of single-lintel-column joints, and the improvement degree varies with the type of viscous dampers. After the viscous damper is installed, the hysteresis curve of the lintel-column joint specimens is fuller; the load bearing capacity is increased by 16.4%-32.9%; the ductility coefficient is increased by 1.5%-12.6%, and the energy dissipation capacity is increased by 49.2%-112.3%. [Conclusions] The mechanical properties of lintel-column joints of pseudo-classic architecture can be markedly improved by the viscous damper.

    参考文献
    相似文献
    引证文献
引用本文

刘海鹏,杜鲁一,董金爽,等.阻尼器对仿古建筑节点力学性能影响研究[J].长沙理工大学学报(自然科学版),2025,22(1):131-141.
LIU Haipeng, DU Luyi, DONG Jinshuang, et al. Influence of damper on mechanical properties of pseudo-classic architecture joint[J]. Journal of Changsha University of Science & Technology (Natural Science),2025,22(1):131-141.